OPERATION: ARGON-HYDROGEN MANIFOLD

7-8

HySpeed HT2000

Instruction Manual

20

After Cutting with Argon-Hydrogen

1. Turn MV1 to the closed position.

2. Disconnect the 14X1 argon-hydrogen cable at the cable connection

point of the argon-hydrogen manifold. See Figure 7-2.

3. Remove the argon-hydrogen plasma gas torch lead from point 1 of

the torch. See Figure 7-5.

4. Connect the machine torch plasma hose from the motor valve console

to point 1 of the torch. See

Connecting the Off-Valve Cable and

Plasma Hose from the Torch to the Motor Valve Console

in Section 4.

5. Remove the nitrogen supply hose from the shield supply connection

of the gas console.

6. Connect the nitrogen supply hose to the N

2

connection of the gas

console. See Figure 7-7.

7. Connect the shield gas supply hose to the shield supply connection of

the gas console. See

Gas Console Connections

in Section 4.

2WRENCHES

Ni

trogen

Figure 7-7 Nitrogen Supply to N

2

Input of Gas Console