Status led troubleshooting – Hypertherm HT2000-200 Volt User Manual

Page 160

Advertising
background image

MAINTENANCE

HySpeed HT2000

Instruction Manual

8-15

19

Problem

Possible Causes

/ Solutions

Status LED Troubleshooting

Be certain that the power supply has been through the

Initial Checks

as outlined earlier in this section before

troubleshooting STATUS LEDs.

When any one of the STATUS LEDs illuminates, there is a fault condition that must be corrected in order for

the power supply to become operational.

See

Section 10 Wiring Diagrams

in this manual for reference.

1. INTERLOCK LED illuminated:

1.1 Door(s) to Remote RHF Console not completely shut.

This LED will extinguish when switches S1 and S2 located in

the RHF console are closed. The switches will close when

the RHF console doors are closed. If the doors are closed,

check pins, connectors and associated wiring for good

continuity from receptacle 1X1 to 2X1.

Repair and/or replace defective component(s), if necessary.

2. TRANSFORMER LED

illuminated:

2.1. Main Transformer T2 or one of the choppers is overheating.

This LED will extinguish when the main transformer (T2) is

operating in a normal temperature range (under 165° C)

and choppers CH1 and CH2 are also operating in a normal

temperature range (under 82°C).

• Check temperature switches (normally closed).

• Check pins, connectors and associated wiring to

temperature switches.

• Leave the fans running, and try restarting the unit after

one hour. If LED still illuminates, one of the choppers or

the main transformer may need to be replaced.