Hypertherm HT2000-200 Volt User Manual

Page 174

Advertising
background image

HySpeed HT2000

Instruction Manual

8-29

22

Preventative Maintenance Schedule

Year________

Daily:

Verify proper inlet gas pressure -- See Instruction Manual,

Specification

section

Verify proper gas flow settings --

Mandatory at every consumable change

-- See Instruction Manual,

Operation

section

Verify proper coolant pressure and temperature --

Water Chillers only

-- See Instruction Manual,

Specification

section

Replace consumables as needed, and inspect torch

Weekly:

Date Completed:

Jan

Feb

March

April

May June

July

Aug

Sept

Oct

Nov

Dec

Week 1

Week 2

Week 3

Week 4

Week 5

Clean power supply with dry, oil free compressed air, or vacuum

Clean torch threads and current ring

Verify cooling fans are working properly

Verify proper coolant level

Monthly:

Date Completed:

Jan

Feb

March

April

May June

July

Aug

Sept

Oct

Nov

Dec

Inspect for loose wire connections

Inspect contacts on main contactor for wear

Inspect pilot arc relay for pitting

Verify proper operation of coolant flow switches

Perform coolant flow test

Check gas console packing nuts for tightness

Perform gas leak test

Inspect cable connections

Bi-Annually:

Date Completed:

Service 1________ Service 2________

Drain coolant system -- See Instruction Manual,

Maintenance

section

Replace coolant filter element - See Instruction Manual,

Maintenance

section

Replace coolant with genuine Hypertherm coolant

Annually:

Date Completed:________

Replace pilot arc relay

Replace main contactor

Hypertherm, Inc. 8/28/00