19

2. Unscrew the four filter cover screws and remove cover to access input voltage connections at TB1 (see

Figure e-2).

3. Insert the power cable through the strain relief (see Figure e-1).

4. Connect leads L1 to U, L2 to V, and L3 to W terminals of TB1 (see Figure e-3). Ensure that all connections

are tight to avoid excessive heating.

5. Connect the ground lead to terminal marked PE at TB1 (see Figure e-3).

Figure e-2

Power Supply with EMI Filter Cover Off – Top View

Filter

TB1