Stainless steel, Above water, 3" under water – Hypertherm HT2000-200 Volt User Manual

Page 120: 100 amps • air plasma / air shield

Advertising
background image

HySpeed HT2000

Instruction Manual

6-25

OPERATION

22

Shield

Arc

Approx.

Material

Plasma Gas Flow Rate %

Gas (Air)

Torch-to-work

Initial Torch

Voltage

Motion

Thickness

Preflow

Cutflow

Pressure

Distance

Piercing Height

Setting

Travel Speed

Delay Time

(inches)

(mm)

(Air %)

(Air %)

(psi)

(inches)

(mm)

(inches)

(mm)

(volts)

(ipm) (mm/min.)

(sec)

Shield

Arc

Approx.

Material

Plasma Gas Flow Rate %

Gas (Air)

Torch-to-work

Initial Torch

Voltage

Motion

Thickness

Preflow

Cutflow

Pressure

Distance

Piercing Height

Setting

Travel Speed

Delay Time

(inches)

(mm)

(Air %)

(Air %)

(psi)

(inches)

(mm)

(inches)

(mm)

(volts)

(ipm) (mm/min.)

(sec)

1/8

3

48

39

60

3/32

2.5

3/16

5

125

140

3560

3/16

5

(53.3

(44.9

(270

1/8

3

1/4

6

130

110

2800

0.5

1/4

6

SCFH)

SCFH)

SCFH)

1/8

3

1/4

6

130

80

2030

0.5

3/8

10

1/8

3

1/4

6

135

55

1400

0.5

1/2

12

1/8

3

140

35

890

5/8

15

.157

4

145

25

635

3/4

20

3/16

5

150

20

510

Stainless Steel

100 amps • Air Plasma / Air Shield

This gas combination gives good cut speed, low dross and is very economical. Some surface nitriding and surface

oxidation of alloying elements can occur.

Notes:

Set air plasma gas inlet pressure to 90 psi (6.2 bar)
Set air shield gas inlet pressure to 90 psi (6.2 bar)

Production cutting above 3/8" (10 mm) not recommended

Above Water

1/8

3

48

39

60

5/64

2

5/32

4

125

135

3400

3/16

5

(53.3

(44.9

(270

1/8

3

1/4

6

130

100

2520

0.5

1/4

6

SCFH)

SCFH)

SCFH)

1/8

3

1/4

6

135

65

1720

0.5

3/8

10

1/8

3

1/4

6

140

45

1120

0.5

1/2

12

1/8

3

145

25

670

3" Under Water

020448
Shield

120837
Retaining cap

020611
Nozzle

020607
Swirl ring

120547
Electrode

Advertising
This manual is related to the following products: