PRE-INSTALLATION

3-12

HySpeed HT2000

Instruction Manual

19

Power Requirements

A power cable for the Water Muffler pump must be provided by the customer. The pumps provided by

Hypertherm take a three-phase input. Part numbers and corresponding voltages are listed below. Input

current information is provided on the motor data plate. Present pump systems all draw less than 20 amps

and cable sizes should be selected accordingly.

Water Muffler System

Water Pump

Part Number

Part Number

Input Voltage

034096 (w/hoses)

028042

240-480 Volt/60 Hz

034100 (w/hoses)

028299

380-415 Volt/50 Hz

034098 (w/hoses)

028308

600 Volts/60 Hz

034097 (wo/hoses)

028042

240-480 Volt/60 Hz

034101 (wo/hoses)

028299

380-415 Volt/50 Hz

034099 (wo/hoses)

028308

600 Volts/60 Hz

Initial Height Sensing (IHS)

The customer must provide the Initial Height Sensing system a source of compressed air to activate the

inductive probes positioning rod.

Air Requirements

Use a clean, dry source of air to prevent possible problems created by moisture and water in the line.

A regulator is required to reduce shop air pressure to

20 psi (1.4 bar)

.

A

1/4 inch

I.D. hose is required between the regulator and the inductive height control module.

In addition to the above requirements for the IHS system, an upper-limit switch and cable may be desirable.

Please refer to

Initial Height Sensing Connections

in the

Installation

section of this manual for further

information.