4.3 LIO Function

4-25

4

„

Analog Input

The SGDH analog input circuit is used for an analog input. Input data is stored in the register
specified on the LIO Definition Screen, via 2-port RAM.

Analog input linearity is only assured between –12.0 and 12.0 (V).

Item

Contents

Input Voltage
Input Impedance

±12 V (max.)
Approx. 14 k

Input
Characteristics*

V data = Input register data 15/32,767

Input register data = V data

32,767/15

Analog Input
Circuit

Register Number

IW0001 (default): Can be set on the Module Configuration Definition
Screen.

A/D

V

IWxxxx

MP940

SGDH

V-REF

SG 6

5

–12 to 12 V

Shar

ed memory

Analog input data is

stored in the register

specified on the LIO

Definition Screen.

12V

-12V

32767

26213

15V

-15V

-26214
-32768

×

×

12V

3

1

25HP-10B

2 kΩ

2

100:1

V-REF

SG

0V

SGDH

5

6

1.8 k

Ω (1/2 W) min.