Yaskawa MP940 User Manual
Page 494

Lists of Parameters
B.3 Switches
B-8
Pn003
Function
Selection
Applica-
tion
Switches
0
Analog Monitor 1
Torque Reference Moni-
tor
Analog Monitor 2
Speed Reference Moni-
tor
0
Motor speed: 1 V/1000 r/min.
2
0
1
Speed reference: 1 V/1000 r/min.
2
Torque reference: 1 V/100%
1
3
Position error: 0.05 V/1 reference unit
4
Position error: 0.05 V/100 reference unit
5
Reference pulse frequency (converted to r/min): 1 V/1000
r/min.
6
Motor speed 4: 1 V/250 r/min.
7
Motor speed 8: 1 V/125 r/min.
8
Fixed parameters (Do not change.)
9
A
B
C
D
E
F
2
Reserved
-
-
0
3
Reserved
-
-
0
Pn005
Function
Selection
Applica-
tion
Switches
0
Brake Control Function
Selection
0
Uses the SERVOPACK brake sequence.
0
1
Uses the host controller brake sequence.
0
1
Reserved
0
0
2
Reserved
0
0
3
Reserved
0
0
Pn10B
0
Mode Switch Selection
0
Uses internal torque reference as the condition (Level set-
ting: Pn10C)
0
1
Uses speed reference as the condition (Level setting:
Pn10D)
2
Uses acceleration as the condition (Level setting: Pn10E)
3
Uses error pulse as the condition (Level setting: Pn10F)
4
No mode switch function available
1
IP control
0
PI control
0
1
IP control
2
Reserved
0
-
0
3
Reserved
0
-
0
Parameter
Digit
Place
Name
Setting
Contents
Default
Setting
×
×