Parameters

6.3.2 Motion Setting Parameter Details

6-30

39

Stopping
Distance
(STOPDIST)

OLC026

-2

31

to 2

31

-1

This parameter is used by the system. Do not use
it.

0

41

Step Travel
Distance (STEP)

OLC028

0 to 2

31

-1

Set the travel distance in reference units for Step
execution for the OWC020: Motion Command
Code.

• Unit: Reference unit

0

43

Zero Point Return
Final Travel
Distance
(ZRNDIST)

OLC02A

-2

31

to 2

31

-1

The machine is moved the distance set for this
parameter after a valid zero point pulse is detected
and then stops when returning to the zero point
using an OWC020: Motion Command Code. The
final point is set as the zero point of the coordinate
system.

• Unit: Reference unit

0

45

Override (OV)

OWC02C

0 to 32767

Set the override for the output speed as a percent-
age of OWC015 or OLC022 (Rapid Traverse
Speed) in 0.01% units.

100,00

This parameter is valid when fixed parameter num-
ber 17: Override Selection (bit 9 of Motion Con-
troller Function Selection Flags) is set to Enabled.

No.

Name

Register

Number

Bit Name

Description

Default

0

1.

2.

3.

4.

Speed refer-

ence

Rapid traverse

speed

Approach

speed

Creep

speed

Zero point

return position

Time

Zero point return final

travel distance

Zero point signal

(phase-C pulse)

Reverse Forward

← →

Zero point

Dog (Decel-

eration LS)

(

OLC022)

100%

(

OWC02C)

Rapid Traverse Speed Output

Rapid Traverse Speed (OLC022) x Override (OWC02C)

= Output speed

Rapid Traverse

Speed

b9 Fixed parame-

ter b9: Override

Selection

Enabled

Disabled

Override

Output

speed