A.F1
A.F1: Power Line Open Phase
Display and Outputs
Note: OFF: Output transistor is OFF (alarm state).
ON: Output transistor is ON.
Status and Remedy for Alarm
Note: A and B tend to occur in a SERVOPACK with a capacity of 500 W or
higher.
CPF00
CPF00: Digital Operator Transmission Error 1
This alarm is not stored in the alarm trace-back function memory.
Cause
Remedy
A
Option Unit is defective.
Replace the Option Unit.
Alarm Outputs
Alarm Code Outputs
ALM Output
ALO1
ALO2
ALO3
OFF
ON
OFF
OFF
Cause
Remedy
A
One phase (L1, L2, or L3) of the
main circuit power supply is discon-
nected.
• Check power supply.
• Check wiring of the main circuit power
supply.
• Check MCCB, noise filter, magnetic con-
tactor.
B
There is one phase where the line
voltage is low.
Check power supply.
C
SERVOPACK defective.
Replace SERVOPACK.
A
At power ON
C
A,B
At main circuit power
supply ON.
Occurred when the control
power turned ON.