4.7 SVA Function
4-73
4
Pn003.0: Analog Monitor 1 and Pn003.1: Analog Monitor 2
Parameter
Set Value
Details
Default
Setting
Pn003.0
(Analog Monitor
1)
2
Select the signal for analog monitoring. A maximum of 2 signals can
be monitored.
2
Pn003.1
(Analog Monitor
2)
0
Pn003.0/
Pn003.1
setting
Details
0
Monitor Signal
Measurement Gain
0
Motor speed
1 V/1000 r/min
1
Speed reference
1 V/1000 r/min
2
Torque reference
1 V/100% rated torque
3
Position error
0.05 V/1 reference unit
4
Position error
0.05 V/100 reference
units
5
Reference pulse fre-
quency
1 V/1000 r/min
6
Motor speed
1 V/250 r/min
7
Motor speed
1 V/125 r/min
8 to E
Reserved constant
-
If using monitoring with the MP940, make the following settings.
• Pn003.0=2: Torque reference (1 V/100% rated torque)
• Pn003.1=0: Motor rotation speed (1 V/1000 r/min.)
You can refer to the data from Analog Monitor 1 and Analog Moni-
tor 2 using the MP940 monitor parameters.
• Torque reference=IWC00E
• Motor rotation speed=IWC00D