Interrupt status – Yaskawa MP940 User Manual
Page 363

Troubleshooting
9.2.4 System Register Configuration
9-18
Interrupt Status
Table 9.10 Interrupt Status
Interrupt Module Details
∗ 1.
Module
mm=01H to 05H: Reserved by system.
mm=06H: MP940/LIO is set to 06.
mm=07H: MP940 counter (PI) is set to 07 Hex.
∗ 2.
Slot
ss = Slot address of interrupted Module.
MP940/LIO is slot 3, so address is 03 Hex.
MP940/counter is slot 5, so address is 05 Hex.
∗ 3.
Causes of Interrupts
xxxx=01H MP940/LIO DI interrupt is always 1 channel.
MP940/counter interrupt is always 1.
Name
Register No.
Remarks
Interrupt count
SW00698
Number of interrupts detected
Modules where interrupt occurred
SW00699
Number of Modules interrupted
for 1 interrupt
Interrupt Module
SW00700
Interrupt module 1
SW00701
SW00702
Reserved by system
SW00703
to
SW00798
Reserved by system
SW00799
15
8
7
0
SW00700
Module *1
Slot *2
mmss Hex
SW00701
Status *3
xxxx Hex