Parameters

6.4.7 Sequence-related Parameters

6-70

Pn509
Momentary Hold Time

ms
20 to 1000

The SERVOPACK turns the servomotor OFF if it detects an instan-
taneous voltage drop in the power supply. This factory setting of 20
ms means that servomotor operation will continue if power is lost
for less than 20 ms.
In the following instances, however, a Servo alarm is generated or
control is lost (equivalent to normal power OFF operation) regard-
less of the parameter setting.

• When an insufficient voltage alarm (A.41) occurs during power

loss with a large servomotor load.

• When control is lost (equivalent to normal power OFF operation)

with loss of the control power supply.

In power loss detection, the status of the main circuit power supply
is detected and OFF status is ignored so servomotor operation will
continue if the servomotor turns back ON within the time set at
parameter Pn509.

20

Speed
Torque
Position

Parameter No. Digit

Name (Setting

Range)

Details

Default

Control

Modes

OFF

Power

supply

voltage

Power loss

1 Pn509 setting > t OFF

Time

2 Pn509 setting t < t OFF

For 1

For 2

Servo ON

Servo OFF

Servo ON