Status and remedy for alarm, A.51, Display and outputs – Yaskawa MP940 User Manual
Page 378

10.2 Troubleshooting
10-11
10
Status and Remedy for Alarm
A.51
A.51: Overspeed
Display and Outputs
Note: OFF: Output transistor is OFF (alarm state).
ON: Output transistor is ON.
Status and Remedy for Alarm
Cause
Remedy
A
The power supply voltage is not within
the range of specifications.
Check power supply voltage.
B
Fuse blown.
Replace SERVOPACK.
C
Rectifying diode defective.
D
SERVOPACK defective.
Alarm Outputs
Alarm Code Outputs
ALM Output
ALO1
ALO2
ALO3
ON
OFF
ON
OFF
Cause
Remedy
A
Servomotor wiring incorrect.
Check and correct wiring. (Check for phase-
U, -V, and -W wiring errors.)
B
Position or speed reference input is
too large.
Lower the reference input values.
C
Incorrect reference input gain set-
tings.
Check and correct parameter settings.
D
Circuit board (1PWB) defective.
Replace SERVOPACK.
D
A, B, C,
A,B.C
During servomotor
operation
Occurred when main cir-
cuit power turned ON.
Occurred when the con-
trol power turned ON.
A, B, C
A, B, C
B, C,
D
A
When servo ON (/S-
ON) signal turned ON
During high-speed
servomotor rotation
after reference input
At power ON
B, C