A.c8, Display and outputs, Status and remedy for alarm – Yaskawa MP940 User Manual
Page 390: A.c9

10.2 Troubleshooting
10-23
10
A.C8
A.C8: Absolute Encoder Clear Error and Multi-turn Limit Setting Error
Display and Outputs
Note: OFF: Output transistor is OFF (alarm state).
ON: Output transistor is ON.
Status and Remedy for Alarm
A.C9
A.C9: Encoder Communications Error
Display and Outputs
Note: OFF: Output transistor is OFF (alarm state).
ON: Output transistor is ON.
Status and Remedy for Alarm
Alarm Outputs
Alarm Code Outputs
ALM Output
ALO1
ALO2
ALO3
ON
OFF
ON
OFF
Cause
Remedy
A
Encoder defective.
Replace servomotor.
B
SERVOPACK defective.
Replace SERVOPACK.
Alarm Outputs
Alarm Code Outputs
ALM Output
ALO1
ALO2
ALO3
ON
OFF
ON
OFF
Cause
Remedy
A
Encoder wiring incorrect or discon-
nected
Check wiring and connectors at
encoder.
B
Encoder defective.
Replace servomotor.
C
SERVOPACK defective.
Replace SERVOPACK.
A,B
A,B
At power ON
When resetting multi-turn
clear encoder alarm
A,B,C
A,B,C
During servomotor
operation
At power ON