Common features specification – HP 30 HP30 User Manual

Page 10

Advertising
background image

ii

Max. Continuous
Baking Time

5 seconds

5 seconds

15 seconds

Controlled by Braking Unit

5

Max. Duty

3 % ED

2 % ED

5 % ED

5 % ED

Weight

[lbs]

10.4 10.4 10.6 10.8 17.0 17.0 30.6 31.7 44.1 44.1

460V Class (40 ~ 100HP)

Model Number

SV xxx ACtionMaster - 4

300

370

450

550

750

HP

40 50 60 75 100

Motor
Rating

1

kW

30 37 45 55 75

Capacity

2

[kVA]

45 56 68 82 100

FLA [A]

61 75 91 110 152

Frequency

0 ~ 400 Hz (0-120Hz for Vector control)

Output
Ratings

Voltage

380 ~ 460 V

3

Voltage

3 Phase, 380 ~ 460 V (

± 10 %)

Input
Ratings

Frequency

50 ~ 60 Hz (

±5 %)

Braking Circuit

Optional (Braking Unit, Resistor)

4

Max. Braking Torque 150%
Max. Continuous
Baking Time

Controlled by Braking Unit

5

Dynamic
Braking

4

Max. Duty

5 % ED

Weight

[lbs]

45 45 63 63 68

Common Features Specification

Control Method

V/F Control,
Sensorless Vector Control (Speed/Torque), Sensored Vector Control (Speed/Torque) Selectable

Frequency Setting
Resolution

Digital Reference: 0.01 Hz (Below 100 Hz), 0.1 Hz (Over 100 Hz)
Analog Reference: 0.03 Hz / 60 Hz

Frequency Accuracy

Digital: 0.01 % of Max. Output Frequency
Analog: 0.1 % of Max. Output Frequency

V/F Ratio

Linear, Square Pattern, User V/F

Overload Capacity

150 % of Rated Current for 1 Min., 200% of Rated Current for 0.5 sec. (Characteristic is Inversely
Proportional to Time)

CONT

ROL

Torque Boost

Manual Torque Boost (0 ~ 20 %), Auto Torque Boost

Operation Method

Key / Terminal / Communication Operation

Frequency Setting

Analog: 0 ~ 10V / 4 ~ 20mA / Additional ports (VR: +12V, 10mA, V2: 0-10V) for Sub-Boards
Digital: Keypad

Start Signal

Forward, Reverse

Multi-Step

Up to 8 Speeds can be Set (Use Multi-Function Terminal)

Multi Step
Accel/Decel Time

0 ~ 6,000 sec, Up to 4 Types can be Set and Selectable for Each Setting (Use Multi- Function
Terminal)
Accel/Decel Pattern: Linear, U-Curve, S-Curve Selectable

OP

ER

AT

IO

N

Input S

ignal

Emergency Stop

Instantly Interrupts the Inverter Output

5

Refer to Chapter 7 Options for DBU and DB Resistors