5 external group [ext – HP 30 HP30 User Manual

Page 74

Advertising
background image

Chapter 5 - Parameter List

5-14

Keypad Display

Setting Range

Code

Description

LCD

7-Segment

LCD

7-Segment

Units

Factory

Default

Adj.

During

Run

Page

I/O-58

Transient Time to 1

st

Step

of Sequence 2

Seq1 / 2T

58

0.1 to 6000 [sec]

0.1

1.1 [sec]

Yes

I/O-59

Steady Speed Time at 1

st

Step of Sequence 2

Seq1 / 2S

59

0.1 to 6000 [sec]

0.1

1.1 [sec]

Yes

Reverse 0

I/O-60

Motor Direction of 1

st

Step

of Sequence 2

Seq1 / 2D

60

Forward 1

- Forward Yes

6-2

I/O-99 Return Code

Not

displayed

99

Not available

[PROG/ENT]

or

[SHIFT/ESC]

- 1 Yes


5.5 External Group [EXT]

EXT group appears only when the corresponding Sub-Board is installed.

Keypad Display

Setting Range

Code

Description

LCD

7-Segment

LCD

7-Segment

Units

Factory

Default

Adj.

During

Run

Page

EXT-00 Jump to Desired Code #

Jump code

Not displayed

0 to 99

Not available

1

1

Yes

6-2

None 0

SUB-A 1
SUB-B 2
SUB-C 3
SUB-D 4
SUB-E 5
SUB-F 6

SUB-G 7

EXT-01 Sub Board Type Display

Sub B/D

01

SUB-H 8

- None

Automa
tically
set

6-2

Speed-L 0

Speed-M 1

Speed-H 2

XCEL-L 3

XCEL-M 4

XCEL-H 5

Dc-brake 6

2nd Func

7

Exchange 8

- Reserved -

9

Up 10

Down 11

3-Wire 12

Ext Trip-A

13

Ext Trip-B

14

iTerm Clear

15

EXT-02 Multi-Function Input

Terminal ‘P4’ Define

P4 define

02

Open-loop 16

- XCEL-L Yes

6-2

Advertising