User selection guide (actionmaster specifications) – HP 30 HP30 User Manual

Page 9

Advertising
background image

i

USER SELECTION GUIDE (ACtionMaster SPECIFICATIONS)

230V Class (1 ~ 30HP)

Model Number

SV xxx ACtionMaster - 2

008

015

022

037

055

075

110

150

185

220

HP

1 2 3 5 7.5 10 15 20 25 30

Motor
Rating

1

kW

0.75 1.5 2.2 3.7 5.5 7.5 11 15 18.5 22

Capacity

2

[kVA] 1.9 3.0 4.5 6.1 9.1 12.2 17.5 22.9 28.2 33.5

FLA

[A]

5 8 12 16 24 32 46 60 74 88

Frequency

0 ~ 400 Hz (0-120Hz for Vector control)

Output
Ratings

Voltage

200 ~ 230 V

3

Voltage

3 Phase, 200 ~ 230 V (

± 10 %)

Input
Ratings

Frequency

50 ~ 60 Hz (

±5 %)

Braking Circuit

On the Board

On the Board

On the Board

(Optional Resistor)

Optional (Braking Unit, Resistor)

4

Average Braking
Torque

100% 100% 150%

150%

Max. Continuous
Baking Time

5 seconds

5 seconds

15 seconds

Controlled by Braking Unit

5

Dynamic
Braking

4

Max. Duty

3 % ED

2 % ED

5 % ED

5 % ED

Weight

[lbs]

10.1 10.1 10.6 10.8 16.5 17.0 30.4 31.5 42.8 44.1


460V Class (1 ~ 30HP)

Model Number

SV xxx ACtionMaster - 4

008

015

022

037

055

075

110

150

185

220

HP

1 2 3 5 7.5

10 15 20 25 30

Motor
Rating

1

kW

0.75 1.5 2.2 3.7 5.5 7.5 11 15 18.5 22

Capacity

2

[kVA]

1.9 3.0 4.5 6.1 9.1 12.2 18.3 22.9 29.7 34.3

FLA

[A]

2.5 4 6 8 12 16 24 30 39 45

Frequency

0 ~ 400 Hz (0-120Hz for Vector control)

Output
Ratings

Voltage

380 ~ 460 V

3

Voltage

3 Phase, 380 ~ 460 V (

± 10 %)

Input
Ratings

Frequency

50 ~ 60 Hz (

±5 %)

Braking Circuit

On the Board

On the Board

On the Board

(Optional Resistor)

Optional (Braking Unit, Resistor)

4

Dynamic
Braking

4

Max. Braking Torque

100%

100%

150%

150%

1

Indicates the maximum applicable capacity when using a 4 Pole motor.

2

Rated capacity (

√ 3*V*I) is based on 220V for 200V class and 440V for 400V class.

3

Maximum output voltage will not be greater than the input voltage. Output voltage less than the input voltage may be programmed.

4

1~5 HP inverters have internal braking resistors as standard. 7.5~10 HP inverters utilize optional braking resistors.

Advertising