Er s t, 3 sub-c board (isolated), Chapter 7 - options – HP 30 HP30 User Manual

Page 172: 1 board configuration

Advertising
background image

Chapter 7 - Options

7-10

7.3 Sub-C Board (Isolated)


7.3.1 Board

Configuration

3P

230/460 V

50/60 Hz

IM

U

V

W

E

R
S
T

FX

RX

BX

RST

JOG

P2

P3

+

FM

5G

30A

30B

30C

AXA

AXC

Output freq
analog meter
(0-10V, 1mA)

*2

P1

Fault output relay
Less than AC 250V, 1A
Less than DC 30V, 1A

VR

V1

I

5G

0

-

10V(1 kohm)

*3

Maximum

current thru

PC: 5mA

CM

NFB

MC

24 V

AM2

AM1

P4

P5

P6

Q1

EXTG

VR

V2

GND

XCEL-L

Multi-function

input

Open collector

Multi-function

input (Less than

25V, 50mA)

ÇÏ

FDT-1

Analog meter output 1
(0-10V, 1mA)

Sub- C

Board

F

M

CM

FWD Run/Stop

REV Run/Stop

Fault reset

JOG

Multi-function input 1

Common Terminal

Multi-function input 2

Multi-function input 3

Emergency brake

Note) 1.

: Main circuit

: Control circuit

2. Output voltage is adjustable up to 12V

3. Three types of External speed signal input available
(V, I, V+I, Refer to Parameter list and description for more details)

.

4 - 20mA (250 ohm)

Speed signal input

Common
terminal for
VR,V1, I

Power supply for
speed signal

(+12V 10mA)

Speed signal input

Factory setting:

Multi-speed

input

(Speed-L,M,H)

Potentiometer
1kohm, 1/2W

Potentiometer
1kohm, 1/2W

Speed signal input

Analog meter output 2
(0-10V, 1mA)

XCEL-M

XCEL-H

Common terminal
for P4-6

Common terminal
for Q1

Multi-function output relay
Less than AC 250V, 1A
Less than DC 30V, 1A
Factory setting:'Run'