HP 30 HP30 User Manual

Page 107

Advertising
background image

Chapter 6 - Parameter description [FU2]

6-15

6.3 Function 2 Group [FU2]

FU2-00: Jump to desired code #






Jumping directly to any parameter code can be
accomplished by entering the desired code number. This
code is available only with LCD keypad.

FU2-01: Previous Fault History 1
FU2-02: Previous Fault History 2
FU2-03: Previous Fault History 3
FU2-04: Previous Fault History 4
FU2-05: Previous Fault History 5
FU2-06: Erase Fault History









This code displays up to five previous fault (trip) status of
the inverter. Use the PROG,

▲ and ▼

key before

pressing the RESET key to check the fault content(s),
output frequency, output current, and whether the inverter
was accelerating, decelerating, or in constant speed at the
time of the fault occurred. Press the ENT key to exit. The
fault content will be stored in FU2-01 through FU2-05
when the RESET key is pressed. For more detail, please
refer to Chapter 7.

[Fault Contents]

Keypad Display

Fault (Trip)

LCD 7-Segment

Over-Current 1

Over Current 1

OC

Over-Voltage Over

Voltage

OV

External Trip Input A

External-A

EXTA

Emergency Stop
(Not Latched)

BX

BX

Low-Voltage Low

Voltage

LV

Fuse Open

Fuse Open

FUSE

Ground Fault

Ground Fault

GF

Over-Heat on Heat sink

Over Heat

OH

Electronic Thermal Trip

E-Thermal

ETH

Over-Load Trip

Over Load

OLT

Inverter H/W Fault

- EEP Error
- ADC Offset

- WDOG Error
- In-Phase Open

HW-Diag

HW

External Trip Input B

External-B

EXTB

Over-Current 2

Arm Short

ASHT

Option Error

Option

OPT

Output Phase Loss

Phase Open

PO

Inverter Over-Load

Inv. OLT

IOLT


Note: There are WDOG error, EEP error, and ADC Offset

for the inverter Hardware Fault, and the inverter will not
reset when H/W fault occurs. Repair the fault before turning
on the power.

Note: When multiple faults occur, only the highest-level

fault will be displayed.











This function erases all fault histories of FU2-01 to FU-05
from the memory.


FU2

► Jump code

00 1

Factory Default:

1

Related Functions: DRV-12 [Fault Display] displays current

fault

status.

FU2

► Last trip-1

01 None

0

01

Factory Default: None

0

FU2

► Last trip-5

05 None

0

05

Factory Default: None

0

FU2

► Erase trips

06 --- No ---

0

06

Factory Default: No

0

Advertising