HP 30 HP30 User Manual

Page 200

Advertising
background image

Chapter 8 - Troubleshooting & Maintenance

8-6

8.4 How to Check Power Components

Before checking the power components, be sure to disconnect AC Input supply and wait until the Main Electrolytic
Capacitors (DCP-DCN) is discharged.



1) Disconnect the power input line (R, S, T) and the inverter output to the motor (U, V, W).
2) Verify whether the inverter terminal R, S, T, U, V, W, B1 (or P/L1), N is shorted or open by changing the polarity of the

tester.

3) Verify capacitor has discharged before testing.
4) The tester should display several mega-ohms when open. The tester can display terminal is shorted for a short time and

then display several mega-ohms because of the electrolytic capacitor. The tester should display x

Ω ~ xx Ω when

terminal is shorted. If all measured values are about the same, individual modules are OK.

4) Diode module and IGBT module checking points:

Test Polarity

Test Polarity

Elements

+ -

Measured

Value

Element

+ -

Measured

Value

R DCP+ Short

R N Open

D1

DCP+ R Open

D4

N R Short

S DCP+ Short

S N Open

D2

DCP+ S Open

D5

N S Short

T DCP+ Short

T N Open

Diode

Module

D3

DCP+ T Open

D6

N T Short

U B1 Short

U N Open

Tr1

B1 U Open

Tr4

N U Short

V B1 Short

V N Open

Tr3

B1 V Open

Tr6

N V Short

W B1 Short

W N Open

IGBT

Module

Tr5

B1 W Open

Tr2

N W Short


R

G

E

G

E

G

E

G

E

G

E

G

E

S

T

U
V
W

G

E

P1 P2

B1

N

Dynamic Braking Unit (Option) for 15~30HP models

N

Charge resistor

Contactor

+

Electrolytic
capacitors

B2

D1

D2

D3

D6

D5

D4

Tr5

Tr3

Tr1

Tr2

Tr6

Tr4

DCP+

Advertising