APPENDIX A - FUNCTIONS BASED ON USE


Set the function properly according to the load and operating conditions. Application and related functions are listed in the
following table.

Use

Related Parameter Code

Accel/Decel Time, Pattern Adjustment

DRV-01 [Acceleration Time], DRV-02 [Deceleration Time],
FU1-05 [Acceleration Pattern], FU1-06 [Deceleration Pattern]

Reverse Rotation Prevention

FU1-03 [Forward, Reverse Prevention]

Minimum Accel/Decel Time

FU1-05 [Acceleration Pattern], FU1-06 [Deceleration Pattern]

Accel/Decel at Continuous Rating Range

FU1-05 [Acceleration Pattern], FU1-06 [Deceleration Pattern]

Braking Operation Adjustment

FU1-07 [Stop Method], FU1-08~11 [DC Braking],
FU1-12~13 [DC braking at start]

Operations for Frequencies Over 60 Hz

FU1-20 [Maximum Frequency],
FU1-25 [Frequency Upper Limit],
I/O-05 [Frequency Corresponding to Max. Voltage of V1],
I/O-10 [Frequency Corresponding to Max. Current of I]

Selecting an Appropriate Output
Characteristics for the Load

FU1-20 [Maximum Frequency],
FU1-21 [Base Frequency]

Motor Output Torque Adjustment

FU1-22 [Starting Frequency],
FU1-26~28 [Torque Boost],
FU1-59~60 [Stall Prevention],
FU2-30 [Rated Motor]

Output Frequency Limit

FU1-23~25 [Frequency Upper/Lower Limit],
I/O-01~10 [Analog Frequency Setting]

Motor Overheat Protection

FU1-50~53 [Electronic Thermal], FU2-30 [Rated Motor]

Multi Step Operation

I/O-12~14 [Define the Multi Function Input Terminals],
I/O-20~27 [Jog, Multi Step Frequency],
FU1-23~25 [Frequency Upper/Lower Limit]

Jog Operation

I/O-20 [Jog Frequency]

Frequency Jump Operation

FU2-10~16 [Frequency Jump]

Timing the Electronic Brake Operation

I/O-42~43 [Frequency Detection Level],
I/O-44 [Multi Function Output]

Displaying the Rotating Speed

DRV-04 [Motor Speed],
FU2-74 [Motor RPM Display Gain]

Function Alteration Prevention

FU2-94 [Parameter Lock]

Energy Saving

FU1-39 [Energy Saving]

Auto Restart Operation After Alarm Stop

FU2-27~28 [Auto Retry]

2

nd

Motor Operation

FU2-81~90 [2

nd

Function]

PID Feedback Operation

FU2-50~54 [PID Operation]

Frequency Reference Signal and Output
Adjusting

I/O-01~10 [Analog Frequency Setting]

Define the Multi-Function Input Terminals

I/O-12~14 [Define the Multi-Function Input Terminals]

Define the Multi-Function Input Terminals

I/O-44 [Multi Function Auxiliary Contact Output Setting]

Commercial Line ⇔ inverter Switchover
Operation

I/O-12~14 [Define the Multi-Function Input Terminals],
I/O-44 [Multi-Function Auxiliary Contact Output Setting]

Frequency Meter Calibration

I/O-40~41 [FM Output]

Operate by Communicating with a Computer

I/O-46 [Inverter No.],
I/O-47 [communication Speed],
I/O-48~49 [Loss of Reference]