HP 30 HP30 User Manual

Page 122

Advertising
background image

Chapter 6 - Parameter Description [FU2]

6-30

FU2-69: Accel/Decel Change Frequency






This function is used to change Accel/Decel ramp at a
certain frequency. This is useful in textile machine
application.

Note: If the multi-function input terminal (I/O-12 ~ I/O-14) is

set to ‘XCEL-L’, XCEL-M’, or XCEL-H’, The Multi-
Accel/Decel Time (I/O-25 ~ I/O-38) has the priority.














[Accel/Decel Change Operation]


FU2-70: Reference Frequency for Accel/Decel






This is the reference frequency for acceleration and
deceleration. If a decided Accel/Decel time from a
frequency to a target frequency is required, set this value
to ‘Delta freq’.

Setting Range

LCD 7-Seg

Description

Max freq

0

The Accel/Decel time is the time that

takes to reach the maximum
frequency from 0 Hz.

Delta freq

1

The Accel/Decel time is the time that
takes to reach a target frequency

from a frequency (currently operating
frequency).





FU2-71: Accel/Decel Time Scale






This is used to change the time scale.




Setting Range

LCD 7-Seg

Description

0.01 sec

0

The Accel/Decel time is changed by 0.01

second. The maximum setting range is
600 seconds.

0.1 sec

1

The Accel/Decel time is changed by 0.1

second. The maximum setting range is
6000 seconds.

1 sec

2

The Accel/Decel time is changed by 1

second. The maximum setting range is
60000 seconds.


FU2-72: Power On Display






This code selects the parameter to be displayed first on
keypad (DRV-00) when the power is turned on.

Setting

Range

Description

0

DRV-00 [Command Frequency]

1

DRV-01 [Acceleration Time]

2

DRV-02 [Deceleration Time]

3

DRV-03 [Drive Mode]

FU2

►Acc/Dec freq

70 Max freq

0

70

Factory Default:

Max freq

0

Related Functions: DRV-01, DRV-02 [Accel/Decel Time]

FU2-71 [Accel/Decel Time Scale]

I/O-25 ~ I/O-38 [1

st

~ 7

th

Accel/Decel Time]

FU2

► Time scale

71 0.1 sec

0.1

71

Factory Default:

0.1 sec

0.1

Related Functions: DRV-01, DRV-02 [Accel/Decel Time]

FU2-70 [Reference Freq. for Accel/Decel]

I/O-25 ~ I/O-38 [1

st

~ 7

th

Accel/Decel Time]

FU2

►Acc/Dec ch F

69 0.00 Hz

0

69

Factory Default:

0.00 Hz

0

Output Frequency

FX

Max. Frequency

Accel/Decel

Change

Frequency

DRV-01 [AccTime]

DRV-02 [DecTime]

I/O-25 [Acc Time1]

I/O-26 [Dec Time1]

FU2

►PowerOn disp

72 0

0

72

Factory Default:

0

0

Advertising