Chapter 6 - Parameter Description [I/O]

6-50

[Auto-A]
This mode will allow the inverter to operate automatically
followed by its pre-programmed sequence. According to
this sequence, eight different steps of Frequency,
Transient Time, Steady Speed time and Motor Direction
can be initiated with only a single multi-function input
contact closure (I/O-12 ~ I/O-14). The sequence and steps
are set in I/O-51 ~ I/O-84.

Step

Frequency

Parameter

Code

Speed-H

(P3)

Speed-M

(P2)

Speed-L

(P1)

Sequence 1

0

0

1

Sequence 2

0

1

0

Sequence 3

1

0

0

Sequence 4

0

1

1

Sequence 5

I/O-50 ~

I/O-84

1 0 1

0: OFF, 1: ON




















[Example 1 of ‘Auto-A’ operation]
























[Example 2 of ‘Auto-A’ operation]


[AUTO B]
This mode can be also used to program up to 8 different
steps as Auto A. However, to switch from one step to
another, an external contact closure set to ‘Go step’ is
required.



















[Example of ‘Auto-B’ operation]

Output Frequency

Time

Seq1 / 2F

Seq1 / 1F

Seq1 / 3F

1T 1S

2T

2S

3T

3S

1D

(Forward)

2D

(Forward)

3D

(Reverse)

P1-CM

‘SEQ-L’

ON

Time

P1-CM

‘SEQ-L’

ON

Output Frequency

Time

ON

Time

P2-CM

‘SEQ-M’

SEQ1 / 2F

SEQ2 / 2F

SEQ1 / 1F

SEQ3 / 2F

SEQ3 / 1F

Sequence 1

Sequence 3

Sequence 2

Time

P1-CM

‘SEQ-L’

ON

Output Frequency

Time

ON

Time

ON

Time

P2-CM

‘SEQ-M’

P3-CM

‘Go step’

ON

ON

ON

ON

Minimum 100msec

SEQ1 / 2F

SEQ2 / 2F

SEQ1 / 1F

SEQ3 / 2F

SEQ3 / 1F

Sequence 1

Sequence 3

Sequence 2

Time