4 sub-d board – HP 30 HP30 User Manual

Page 174

Advertising
background image

Chapter 7 - Options

7-12

7.4 Sub-D Board


7.4.1 Board

Configuration


3 Phase

230/460V

50/60Hz

IM

U

V

W

E

R
S
T

FX

RX

BX

RST

JOG

P2

P3

+

FM

5G

30A

30B

30C

AXA

AXC

P1

Multi-function
output
Less than
AC 250V,1A

Fault output
relay
Less than
AC 250V,1A

VR

V1

I

5G

*3

CM

NFB

MC

24 V

CM
P4

P5

P6

Q1
Q2

EXTG

VR

V2

Voltage input

(+12V 10mA)

5G

Potentiometer

1 kohm,1/2W

Multi-function output

FDT-1

FDT-2

E

Encoder

A -

A +

B+

BOC

+15V

GND

(5V input)

+5V

Ground T

for +15V, +5V

AOC

(15V input)

Multi-function input 4

Encoder

(OC)

Multi-

function

input

Power supply for

speed signal

FWD Run/Stop

REV Run/Stop

Fault reset

JOG

Multi-function input 1

Common Terminal

Multi-function input 2

Multi-function input 3

Emergency brake

Maximum

current thru

PC: 5mA

Common
terminal for
VR,V1, I

Power supply for
speed signal
(+12V 10mA)

Speed signal input
4 - 20mA (250 ohm)

Factory setting:
Multi-speed
input
(Speed-L,M,H)

Speed signal input
10V (1kohm)

Encoder

(LD)

Multi-function input 5
Multi-function input 6

Speed signal input

B -

Note) 1.

: Main circuit

: Control circuit

2. Output voltage is adjustable up to 12V

3. Three types of External speed signal input available
(V, I, V+I, Refer to Parameter list and description for more details)

.

Sub- D

Board

*2

Advertising