Chapter 8 - Troubleshooting & Maintenance

8-4

Protective

Function

Cause

Remedy


2) Incorrect encoder parameter setting
3) Sub-B board or Encoder fault

correctly.
2) Check parameters of EXT-14,15,16 are set correctly.
3) Replace the faulty Sub-B board or Encoder to a new
one.

Option Fault Faulty option connector connection

Check option connection.

H/W Fault

1) Wdog error (CPU fault)
2) EEP error (memory fault)
3) ADC Offset (current feedback circuit fault)

Replace inverter

Communication

Fault

1) Faulty connection between inverter and keypad
2) Inverter CPU malfunction

1) Check connector
2) Replace inverter

Operating

Method when the

Speed

Reference is

Lost

LOP (Loss of reference from the Option),
LOR (Remote)
LOV (V1),
LOI (I),
LOX (Sub-V2, ENC)

Eliminate cause of fault

Inverter

Overload

1) Load is larger than inverter rating
2) Selected incorrect inverter capacity

1) Increase motor and/or inverter capacity
2) Select correct inverter capacity

Magnetic

contactor fault

1) Damaged M/C operation detection contact

2) M/C malfunction

1) Check M/C operation detection contact is working
properly.
2) Check M/C is working properly. Replace it, if needed.