2 operation example – HP 30 HP30 User Manual

Page 55

Advertising
background image

Chapter 4 – Operation Examples

4.2 Operation Example

Operation
Example (1)

V/F Control + Analog Voltage Input (V1) + Operation via Terminal (FX/RX)

[Operation condition]

-. Control mode : V/F control
-. Frequency command : 50[Hz] analog input via V1 terminal
-. Accel/Decel time : Accel – 15 [Sec], Decel – 25 [Sec]
-. Drive mode: Run/Stop via FX/RX terminal

[Wiring]

R
S

T

G

U
V

W

B1

B2

FX
RX

BX
RST

JOG
P1

P2
P3
CM

VR
V1
5G

FM

5G

30A
30C
30B

AXA
AXC

IM

3P

AC

input

Potentiometer

1[kohm],1/2W

S/W

Step

Parameter setting

Code

Description

1

Control Mode Selection

FU2-39

Set it to 0 {V/F}

2

Drive Mode

DRV-3

Set it to Fx/Rx-1.

3

Frequency Mode

DRV-4

set V1 Analog input value in frequency mode

4

50[Hz] freq command

setting

DRV-0

set freq command 50[Hz] via V1(potentiometer)

5

Accel/Decel time

DRV-2
DRV-3

Set Accel time to 15 [Sec] in DRV-2
Set Decel time to 25 [Sec] in DRV-3

6

Terminal FX

Motor starts to rotate in Forward direction at 50Hz with Accel time 15 [sec]
when FX terminal is turned ON.
Motor decelerates to stop with Decel time 25[sec] when FX terminal is
turned OFF.

7

Terminal RX

When RX terminal is turned ON motor starts to rotate in Reverse direction
at 50[Hz] with Accel time 15 [Hz]. When it is OFF, motor decelerates to
stop with Decel time 25 [Sec].





Advertising