3 battery cabinet installation, 4 integrated distribution cabinet installation, 5 integrated accessory cabinet installation – Powerware 9390 UPS 100160 kVA User Manual

Page 31: 6 ups sidecar wiring, Battery cabinet installation, Integrated distribution cabinet installation

Advertising
background image

INSTALLING THE UPS SYSTEM

EATON Powerware

®

9390 UPS (20–80 kVA) Installation and Operation Manual

S 164201603 Rev 2 www.powerware.com

4-5

10. If installing the cabinet permanently, retain the shipping brackets and hardware;

otherwise, discard or recycle the pallet and rear bracket in a responsible manner.

11. If permanently mounting the system, proceed to Step 15; otherwise, continue to

Step 12.

W

A

R

N

I

N

G

The front anti-tip/shipping bracket must be reinstalled; otherwise, injury and damage to the UPS may result
when removing components during service. If the bracket is not reinstalled, the cabinet may tip and cause
serious injury and damage.

12. Secure the UPS cabinet in position by lowering the leveling feet until the cabinet

is not resting on the casters and the cabinet is level.

13. Using the retained hardware, reinstall the front anti-tip/shipping bracket (bracket

with wider base) removed in Step 6 to the front of UPS cabinet with the angle
facing outward and adjusted level with the floor (see Figure 4‐1).

14. If installing battery and distribution cabinets, proceed to paragraphs 4.3 and 4.4;

otherwise, proceed to paragraph 4.7.

15. Using the retained hardware, reinstall the shipping brackets removed in Step 5 to

the front and rear of the UPS cabinet with the angle facing outward (see
Figure 4‐1 and Figure 4‐2).

16. Secure the cabinet to the floor with customer-supplied hardware.

17. If installing battery and distribution cabinets, proceed to paragraphs 4.3 and 4.4;

otherwise, proceed to paragraph 4.7.

4.3

Battery Cabinet Installation

To install the battery cabinet, refer to the Powerware 9390 Integrated Battery Cabinet
(Models IBC-S and IBC-L) Installation Manual
. After the battery cabinet is installed,
return to paragraph 4.7 to wire the UPS and battery cabinet.

4.4

Integrated Distribution Cabinet Installation

To install and wire an IDC, refer to the Powerware 9390 Integrated Distribution
Cabinet (80 kVA) Installation and Operation Manual
. After the IDC is installed and
wired, return to paragraph 4.7 to complete the UPS cabinet wiring.

4.5

Integrated Accessory Cabinet Installation

To install and wire an IAC, refer to the Powerware 9390 Integrated Accessory Cabinet
(IAC-B and IAC-T Configurations) Installation and Operation Manual
or the Powerware
9390 Integrated Accessory Cabinet (IAC-D Configuration) Installation and Operation
Manual
. After the IAC is installed and wired, return to paragraph 4.7 to complete the
UPS cabinet wiring.

4.6

UPS Sidecar Wiring

To wire a UPS Sidecar, refer to the Powerware 9390 UPS Sidecar Installation and
Operation Manual
. After the UPS Sidecar is wired, return to paragraph 4.7 to
complete the UPS cabinet wiring.

Advertising