IDEC FL1E SmartRelay User Manual

Page 104

Advertising
background image

Programming IDEC SmartRelay

90

IDEC SmartRelay Manual

Setting the time

Set the time T = 12:00 minutes:
1. Move the cursor to the first digit:

Press or

2. Select the digit ’1’:

Press or

3. Shift the cursor to the second digit:

Press or

4. Select digit ’2’:

Press or

5. Move the cursor to the unit:

Press or

6. Select the timebase ’m’ (for minutes):

Press or

Showing/hiding parameters - the parameter protection mode

If you want to show/hide the parameter and allow/prevent its

modification in parameter assignment mode:
1. Move the cursor to the protection mode: Press or
2. Select the protection mode:

Press or

The display should now show:

T=12:00m

B2 +R

Protection mode + : The value
of the time T can be modified in
parameter assignment mode

Protection mode - : The
value of the time T is
hidden in parameter
assignment mode

or

T=12:00m

B2 –R

3. Confirm your entries with:

OK

Enabling/disabling retentivity

To decide whether you want to retain your current data after

a power failure or not:
1. Move the cursor to the retentivity setting: Press or
2. Select the retentivity setting:

Press or

The display now shows:

T=12:00m

B2 –R

Retentivity R: Current data
is retained

Retentivity /: Current data is
not retained

or

T=12:00m

B2 –/

3. Confirm your entries with

OK

Advertising