12 twelve-month time switch, Twelve-month time switch – IDEC FL1E SmartRelay User Manual

Page 169

Advertising
background image

IDEC SmartRelay functions

IDEC SmartRelay Manual

155

4.4.12 Twelve-month time switch

Short description

The output is controlled by means of a configurable on/off

date. You can configure the timer to activate on a yearly,

monthly, or user

-

defined time basis. With any mode, you can

also configure the timer to pulse the output during the

defined time period. The time period is configurable within

the date range of January 1, 2000 to December 31, 2099

Note

Because FL1E-H12SND does not have a real-time clock, the
twelve-month time switch is not available for this version.

Timing diagrams

Example 1: Yearly mode on, Monthly mode off, Pulse Off,

On Time = 2000

06

01, Off Time = 2099

08

31: Every year

on June 1 the timer output switches on and remains on until

August 31.

B6 2+
ON :
YYYY–MM–DD
2000–06–01

B6 1+
Yearly = On
Monthly=Off
Pulse =Off

B6 3+
OFF :
YYYY–MM–DD
2099–08–31

Symbol in IDEC

SmartRelay

Wiring

Description

Cam
parameter

At the Cam parameter, you configure
the timer mode, the on-/off-times for
the timer, and whether the output is a
pulse output.

Output Q

Q is set when the configured cam is
switched on.