B33 +/ on= start=on, B33 +/ on/off start=on – IDEC FL1E SmartRelay User Manual

Page 220

Advertising
background image

IDEC SmartRelay functions

206

IDEC SmartRelay Manual

Functional description

In parameter assignment mode, the output is set with a

signal at input En, if the ’’Switch’ parameter is set to ’On’ and

confirmed with OK. Whether the function was configured for

pushbutton or switching action is of no concern here.
The output is reset to ’0’ in the following three cases:

• After a 1 to 0 transition at input En

• When the function was configured for momentary

pushbutton action, and one cycle has expired since it was

switched on

• When the position ’Off’ was selected at the ’Switch’

parameter and confirmed with OK in parameter

assignment mode

If retentivity is not set, output Q is initialized after a power

failure according to your configuration at the ”Start”

parameter.

Setting the Par parameter

View in programming mode (example):
1. Select the ’Softkey’ function.
2. Select input En and confirm with OK. The cursor is now

positioned below ’Par’.

3. Change to the input mode of ’Par’:

Confirm with OK

(the cursor is now positioned to ’On’)

B33 +/
On=
Start=On

The status is not retentive
The function is set for “momentary

pushbutton” action
Q is set in the first cycle after the

program start

To change ’Par’ to ’Switch’ action and the initialization status

after the program start:
4. To select ’Momentary pushbutton’ or ’Switch’ action:

Press or

B33 +/
On/Off
Start=On

The status is not retentive

“Switch” function

Q is reset in the first cycle after the

program start