IDEC SmartRelay functions

150

IDEC SmartRelay Manual

If retentivity is not set, output Q and the expired time are

reset after a power failure.

Setting the Par parameter

Note the defaults specified in Chapter 4.3.2.

Note

T, T

!

and T

!L

must all have the same timebase.

View in programming mode (example):

B5 1+R
T

=60:00s

TL

=10:00s

Protection mode and retentivity

Off-delay
Permanent light on-time

Press

B5 2
T!

=30:00s

T!L =20:00s

Start of the off-warning period

(T - T!)

Off-warning time

View in parameter assignment mode (example):

B5 1
T

=60:00s

TL =10:00s
Ta =06:00s

Current value of the time T

L

or T

4.4.11 Seven-day time switch

Short description

The output is controlled by means of a configurable on/off

date. The function supports any combination of weekdays.

You select the active weekdays by hiding the inactive days.