IDEC SmartRelay functions

IDEC SmartRelay Manual

143

Parameters TH and TL

Note the information on parameter T in Chapter 4.3.2.
The pulse width TH and the interpulse width TL can be

provided by the actual value of another already-programmed

function. You can use the actual values of the following

functions:
• Analog comparator (actual value Ax - Ay, see Chapter

4.4.18)

• Analog trigger (actual value Ax, see Chapter 4.4.16)
• Analog amplifier (actual value Ax, see Chapter 4.4.20)
• Analog multiplexer (actual value AQ, see Chapter 4.4.26)
• Analog ramp control (actual value AQ, see Chapter

4.4.27)

• Analog math (actual value AQ, see Chapter 4.4.30)
• PI controller (actual value AQ, see Chapter 4.4.28)
• Up/down counter (actual value Cnt, see Chapter 4.4.13)
Select the required function by the block number. The

timebase is configurable. For information on valid ranges

and parameter defaults, refer to Chapter 4.4.1.

En

Inv

T

H

Q

T

L

T

H

T

L

T

H

T

L

T

H

Timing diagram

Functional description

You can configure the pulse/interpulse width at the T

H

(Time

High) and T

L

(Time Low) parameters.

Input Inv can be used to invert the output signal, provided the

block is enabled with a signal at input EN.
If retentivity is not set, output Q and the expired time are

reset after a power failure.