Normal operation error and warning, Error and warning/ troubleshooting status messages – Anritsu 682XXB User Manual

Page 174

Advertising
background image

5-8

682XXB/683XXB MM

Error Message

Description

ERR

Continued:
(2) The external FM modulating signal exceeds the input
voltage range. In addition, the message “Reduce FM
Input Level
” appears at the bottom of the FM status
display.
(3) A pulse parameter setting is invalid for the current
pulse modulation state, as follows:

Single Pulse Mode:

Free Run or Gated Trigger:

Width1 > PRI

Delayed Trigger:

Delay1 + Width1 > PRI

Doublet Pulse Mode:

Free Run Trigger:

Width1 > Delay2 or
Width1 + (Delay2 – Width1) + Width2 > PRI

Delayed Trigger:

Width1 > Delay2 or
Delay1 + Width1 + (Delay2 – Width1) +Width2 > PRI

External Trigger with or without Delay:

Width1 > Delay2

Triplet Pulse Mode:

Free Run Trigger:

Width1 > Delay2 or Width2 > Delay3 or
Width1 + (Delay2 – Width1) + Width2 +

(Delay3 – Width2) + Width 3 > PRI

Delayed Trigger:

Width1 > Delay2 or Width2 > Delay3 or
Delay1 + Width1 + (Delay2 – Width1) + Width2 +

(Delay3 – Width2) + Width 3 > PRI

External Trigger with or without Delay:

Width1 > Delay2 or Width2 > Delay3

Quadruplet Pulse Mode:

Free Run Trigger:

Width1 > Delay2 or Width2 > Delay3 or
Width3 > Delay4 or
Width1 + (Delay2 – Width1) + Width2 + (Delay3 –

Width2) + Width3 + (Delay4 – Width3) + Width4
> PRI

Delayed Trigger:

Width1 > Delay2 or Width2 > Delay3 or
Width3 > Delay4 or
Delay1 + Width1 + (Delay2 – Width1) + Width2 +

(Delay3 – Width2) + Width3 + (Delay4 – Width3) +
Width4 > PRI

External Trigger with or without Delay:

Width1 > Delay2 or Width2 > Delay3 or
Width3 > Delay4

Table 5-2.