±15VA Supply Problems

This supply provides

±15 volts to the Function Generator, PIN Control,

ALC, FM, and Analog Instruction circuits.

Step 5.

Perform the following procedure to isolate malfunctions to
the

±15VA supply and outlying load circuits.

a.

Place the

LINE

switch to

STANDBY

.

b.

Replace the A15 PCB assembly.

c.

Place the

LINE

switch to

OPERATE

and measure the

±15VA voltages per Table 5-7.

G

If the voltages are correct, the problem is cleared.

G

If the voltages are incorrect, go to step d.

d.

Place the

LINE

switch to

STANDBY

.

e.

Remove the A8, A9, A10, A11, and A12 PCBs.

f.

Place the

LINE

switch to

OPERATE

and measure the

±15VA voltages.

G

If the voltages are correct, go to step g.

G

If the voltages are still incorrect, contact your local

ANRITSU

service center for assistance.

g.

Place the

LINE

switch to

STANDBY

, then install one of

the removed PCBs.

h. Place the

LINE

switch to

OPERATE

and measure the

±15VA voltages.

i.

Continue steps g and h until the faulty PCB is located.