TABLES

Error 135 Modulator or Driver Failed

Description: Error 135 indicates a failure of the modulator in the
switched filter assembly or the modulator driver circuitry on the A9
PIN Control PCB.

Step 1.

Replace the A9 PCB and run self-test.

G

If error 135 is not displayed, the problem is cleared.

G

If error 135 is still displayed, go to step 2.

Step 2.

Replace the switched filter assembly and run self-test again.

G

If error 135 is not displayed, the problem is cleared.

G

If error 135 is still displayed, contact your local

ANRITSU

service center for assistance.