Troubleshooting, Troubleshooting tables – Anritsu 682XXB User Manual

Page 216

Advertising
background image

5-50

682XXB/683XXB MM

Error 139 32-40 GHz SDM Section Failed
Error 140 25-32 GHz SDM Section Failed
Error 141 20-25 GHz SDM Section Failed

Description: Each of these error messages indicates a failure in a
switched doubler filter path within the SDM. The 682XXB/683XXB
will not produce an RF output in the frequency range of the failed
switched doubler filter path.

Step 1.

Set up the 682XXB/683XXB as follows:

a.

682XXB Setup:
CW/SWEEP SELECT: Step
F1: 2.000 GHz
F2: 40.000 GHz
Number of Steps: 400
L1: +1.00 dBm

683XXB Setup:
CW/SWEEP SELECT: Analog
F1: 2.000 GHz
F2: 40.000 GHz
Sweep Time: 0.100 Sec
L1: +1.00 dBm

Step 2.

Connect the X input of an oscilloscope to the 682XXB/
683XXB rear panel

HORIZ OUT

connector.

Step 3.

Using the oscilloscope, check the PIN switch drive voltages
at A9TP11, A9TP15, and A9TP24 (shown in Table 5-23).

G

If the PIN switch drive voltages are correct, replace the
SDM.

G

If the PIN switch drive voltages are not correct, replace
the A9 PCB.

Table 5-22.

Error Messages 138, 139, 140, and 141 (2 of 2)

TROUBLESHOOTING

TROUBLESHOOTING

TABLES

Test Point

Active Frequency

Range

Active

Voltage

Inactive

Voltage

A9TP9

0.01 to 20 GHz

+20V

–15V

A9TP11

20 to 25 GHz

+20V

–15V

A9TP15

25 to 32 GHz

+20V

–15V

A9TP24

32 to 40 GHz

+20V

–15V

Table 5-23.

SDM PIN Switch Drive Voltages

Advertising