Troubleshooting, Troubleshooting tables – Anritsu 682XXB User Manual

Page 189

Advertising
background image

682XXB/683XXB MM

5-23

±15VLP Supply Problems

This supply provides

±15 volts to the Pulse Generator and the Refer-

ence, Coarse, Fine, and YIG Loop circuits.

Step 6.

Perform the following procedure to isolate malfunctions to
the

±15VLP supply and outlying load circuits.

a.

Place the

LINE

switch to

STANDBY

.

b.

Replace the A15 PCB assembly.

c.

Place the

LINE

switch to

OPERATE

and measure the

±15VLP voltages per Table 5-7.

G

If the voltages are correct, the problem is cleared.

G

If the voltages are incorrect, go to step d.

d.

Place the

LINE

switch to

STANDBY

.

e.

Remove the A3, A4, A5, A6, and A7 PCBs.

f.

Place the

LINE

switch to

OPERATE

and measure the

±15VLP voltages.

G

If the voltages are correct, go to step g.

G

If the voltages are still incorrect, contact your local

ANRITSU

service center for assistance.

g.

Place the

LINE

switch to

STANDBY

, then install one of

the removed PCBs.

h. Place the

LINE

switch to

OPERATE

and measure the

±15VLP voltages.

i.

Continue steps g and h until the faulty PCB is located.

Table 5-6.

Error Messages 105 and 106 (5 of 10)

TROUBLESHOOTING

TROUBLESHOOTING

TABLES

Advertising