3-16 Pulse Modulation Test: RF On/Off Ratio

Test Procedure (1 GHz)

Lower Limit

Measured Value

Upper Limit

Set F1 to 1.10 GHz

Measure and record the peak of the signal on the Spectrum
Analyzer. (Measured signal must be >60 dB below top graticule
to meet specification; this represents an On/Off Ratio of >80 dB.) .

60 dB

_______ dB

N/A

Test Procedure (5 GHz)

Set F1 to 5.0 GHz

Measure and record the peak of the signal on the Spectrum
Analyzer. (Measured signal must be >60 dB below top graticule
to meet specification; this represents an On/Off Ratio of >80 dB.) .

60 dB

_______ dB

N/A

3-17 Phase Modulation Tests

F

M Imput Sensitivity Procedure

(Wide

F

M Mode)

Lower Limit

Measured Value

Upper Limit

Set F1 to 5.0 GHz

Record the

F

M deviation displayed on the 68259B/68359B . . . . . . . . . . . . . .

_______rad

Calculate and record the

F

M accuracy . . . . . . . . . . . . . . .

93.7%

_________ %

106.3%

F

M Imput Sensitivity Procedure

(Narrow

F

M Mode)

Set F1 to 5.0 GHz

Record the

F

M deviation displayed on the 68259B/68359B . . . . . . . . . . . . . .

_______rad

Calculate and record the

F

M accuracy . . . . . . . . . . . . . . .

93.7%

_________ %

106.3%