5-30

682XXB/683XXB MM

Error 110 The 100MHz Reference is not Locked to the High
Stability 10MHz Crystal Oscillator

Description: The reference loop is not phase-locked to the Option 16
high stability 10 MHz crystal oscillator.

Step 1.

Disconnect the cable from A3J6.

Step 2.

Using an oscilloscope, verify the presence of a 10 MHz signal
at the end of the cable. The signal amplitude should be
³1 volt (into 50W).

G

If present, replace the A3 PCB.

G

If not present, replace the Option 16 crystal oscillator
assembly.

Table 5-8.

Error Messages 108, 109 and 110 (2 of 2)

TROUBLESHOOTING

TROUBLESHOOTING

TABLES

A5 Fine Loop

Error 111 Fine Loop Osc Failed

Description: One or more of the oscillators within the fine loop is not
phase-locked.

Step 1.

Disconnect cable W121 at A5J5.

Step 2.

Using a spectrum analyzer, verify the presence of a +3 dBm
±5 dB, 10 MHz signal at the end of the cable.

G

If present, go to step 9.

G

If not present, go to step 3.

Step 3.

Disconnect cable W121 at A4J7.

Step 4.

Using the spectrum analyzer, verify the presence of the
+3 dBm

±5 dB, 10 MHz signal at A4J7.

G

If present, replace the cable W121.

G

If not present, go to step 5.

Step 5.

Disconnect cable W105 at A4J6.

Table 5-9.

Error Message 111 (1 of 2)