PHASE MODULATION
(

F

M) CALIBRATION

This procedure provides the steps necessary to perform phase modula-
tion (

FM) calibration for 682XXB/683XXBs with Option 6. This con-

sists of calibrating the FM Variable Gain Control DAC and the

FM

Flatness DAC for input sensitivities in Narrow and Wide

FM modes.

Equipment
Setup

Connect the equipment, shown in Figure 4-15, as
follows:

1. Interface the PC to the 682XXB/683XXB by per-

forming the initial setup procedure, pages 4-7 to
4-12.

2. Connect the 682XXB/683XXB rear panel

10 MHz

REF OUT

to the Spectrum Analyzer External

Reference Input.

3. Connect the Function Generator Output to the

BNC tee. Connect one leg of the tee to the
682XXB/683XXB front panel

FM IN (

F

M IN)

. Con-

nect the other leg of the tee to the DMM input.

682XXB/683XXB MM

4-51

PHASE MODULATION

CALIBRATION

(

FM) CALIBRATION

Serial

I/O

682XXB / 683XXB

COM1

or

COM2

IBM-Compatible PC

Function

Generator

10 MHz

REF OUT

EXT REF

INPUT

RF

IN

Spectrum

Analyzer

OUTPUT

FM IN

(

ΦM IN)

RF

OUTPUT

BNC
Tee

INPUT

DMM

Figure 4-15.

Equipment Setup for

.M Calibration