Block diagrams 2-21, 2-22, 2-27, 2-28, Block diagram, 2-21 - 2-22, 2-27 - 2-28, Functional rf deck description assemblies – Anritsu 682XXB User Manual

Page 49

Advertising
background image

FM

MAIN

BIAS

Modulator

Control

Switch

Control

>+17 dBm

500 MHz

Down Converter Assy.

D27330

8.4-20 GHz

2-8.4 GHz

>+4dBm

0.01 - 40 GHz

110 dB

Step

Attenuator

(Option)

Directional

Coupler

Control

3.3 GHz LPF

5.5 GHz LPF

8.4 GHz LPF

13.5 GHz LPF

Level

Control

6.51 - 8.5 GHz

J5

J2

J3

LPF

6.5 GHz

J3

J1

Sampler

(-20 dBm

to

-27dBm)

J6

J2

Level

Control

RF Output

J1

2-20 GHz

YIG Oscillator

Switch

Control

Bias

20 - 40 GHz

>+8.5 dBm

Switched Filter Assy. - D25015 (Standard)

- D26350 (Option 15B)

0.01 - 2 GHz

>+16 dBm

8.5 GHz LPF

J2

RF Path for 20 GHz Models

20 - 25 GHz BPF

25 - 32 GHz BPF

32 - 40 GHz BPF

x2

>+15 dBm (Std.)

20 GHz LPF

>+20 dBm (Opt. 15B)

Switched Doubler Module - D28535

(40 GHz Models)

J1

Switch

Control

Bias

20 - 26.5 GHz

>+8.5 dBm

J2

20 - 26.5 GHz BPF

x2

Switched Doubler Module - ND40843

(26.5 GHz Models)

J1

Modulator

Pulse

J7

NOTES

1. Down Converter Assy not installed in Models

68237B/68337B, 68253B/68353B, and 68263B/68363B.

2. Switched Doubler Module not installed in Models

68237B/68337B and 68247B/68347B.

FUNCTIONAL

RF DECK

DESCRIPTION

ASSEMBLIES

682XXB/683XXB MM

2-21

Figure 2-4. Block Diagram of the RF Deck Assembly for all
£40 GHz Models (except 682X5B/683X5B Models)