Test procedure 3-23, Test procedure -23 – Anritsu 682XXB User Manual

Page 83

Advertising
background image

Test
Procedure

The following procedure lets you measure the RF
output single sideband phase noise levels to verify
that they meet specifications.

NOTE

The following technique is a measurement
of phase noise and AM noise. To avoid erro-
neous results, on the 682XXB/683XXB
DUT set L1 for maximum leveled output
power and select External Detector level-
ing. This will prevent any AM noise from
degrading the phase noise measurements.

1. Set up the 682XXB/683XXB DUT as follows:

a. Reset the instrument by pressing

SYSTEM

,

then

Reset

. Upon reset the CW Menu is dis-

played.

b. Press

Edit F1

to open the current frequency

parameter for editing.

c. Set F1 to the frequency indicated on the Test

Record.

d. Press

Edit L1

to open the current power level

parameter for editing.

e. Set L1 to the maximum leveled power level for

the instrument being tested (refer to Table 3-2,
page 3-6).

2. Set up the 682XXB/683XXB LO as follows:

a. Reset the instrument by pressing

SYSTEM

,

then

Reset

. Upon reset the CW Menu is dis-

played.

b. Press

Edit F1

to open the current frequency

parameter for editing.

c. Set F1 to a frequency that is 1 MHz lower than

the 682XXB/683XXB DUT frequency set in
step 1.c.

d. Press

Edit L1

to open the current power level

parameter for editing.

e. Set L1 to the maximum leveled power level for

the instrument model (refer to Table 3-2).

682XXB/683XXB MM

3-23

PERFORMANCE

SINGLE SIDEBAND

VERIFICATION

PHASE NOISE TEST

Advertising