MS-9200UDLS Series Manual — P/N 52750:H 4/14/2014

Product Description

Accessories

ANN-LED Annunciator Module

The ANN-LED and ANN-RLED annunciator modules provide LED annunciation of general sys-
tem faults and input zones/points when used with a compatible FACP. The ANN-LED module pro-
vides alarm (red), trouble (yellow) and supervisory (yellow) indication for up to ten input zones or
addressable points. The ANN-RLED provides alarm (red) indication for up to 30 input zones or
addressable points. Multiple ANN-(R)LED modules may be used for full system coverage.

ANN-RLY Annunciator Module

The ANN-RLY relay module provides 10 programmable Form-C relays when used with a compat-
ible FACP.

ANN-LC Lite-Connect Module

The ANN-LC module provides a multi-FACP system where a single communicator and phone line
for Alarm, Supervisory, and Trouble reporting to a central station are shared using fiber-optic
cables. Each FACP requires its own ANN-LC. The FACP/ANN-LC pair are referred to as a node
on the fiber circuit. Each node requires a unique node address. The node communicates with other
nodes via fiber-optic media from one ANN-LC to the next.

1.7.11 Legacy ACS Series LED Zone Type Annunciators

The legacy ACS annunciators may not be used if new ANN-BUS annunciators are being used on
the primary ANN-BUS connector (TB9) due to incompatible serial communication protocols.
Refer to “Guidelines” on page 22 for rules governing the use of various annunciator types.

The legacy ACS Series Annunciators remotely display alarm and trouble status as well as system
status. In addition, they can provide remote Acknowledge, Silence, Reset and Drill functions. For
more detailed information, refer to the appropriate annunciator manual. Following is a list of
annunciators which can be used with the MS-9200UDLS.

ACM-16ATF

*

Annunciator Control Module annunciates 16 zones with 16 red alarm LEDs

and 16 yellow trouble LEDs. In addition, it has a System Trouble LED, an On Line/Power
LED and a local piezo sounder.

AEM-16ATF Annunciator Expander Module annunciates 16 zones with 16 red alarm LEDs
and 16 yellow trouble LEDs

ACM-32AF

*

Annunciator Control Module annunciates 32 alarm zones with 32 red LEDs. In

addition, it has a System Trouble LED, an On Line/Power LED and a local piezo sounder. It
also has a switch for local piezo silence.

AEM-32AF Annunciator Expander Module annunciates 32 alarm zones with 32 red LEDs

* In Canada, the color red must be used to indicate active alarm inputs. Yellow indicates supervi-
sory, burglary or trouble signals. Green indicates the presence of power, or an activated output.

LCD-80F/LCD-80FC Remote Fire Annunciator/Indicator

The LCD-80F/LCD-80FC annunciator/Indicator is an 80-character backlit LCD remote fire annun-
ciator/indicator that is capable of displaying English language text. Communications between the
control panel and the annunciator is accomplished over a serial interface employing the EIA-485
communication standard. Up to 32 LCD-80F/LCD-80FC annunciators/indicators may be con-
nected to the EIA-485 circuit. The annunciators/indicators may be powered from the host FACP or
a remote UL listed filtered power supply such as the FCPS Series. For more detailed information,
refer to the LCD-80F and LCD-80FC manuals.

!

WARNING: RISK OF ELECTRICAL SHOCK AND EQUIPMENT DAMAGE
DISCONNECT ALL SOURCES OF POWER (AC AND DC) BEFORE INSTALLING OR REMOVING
ANY MODULES OR WIRING.