Error messages, System messages, Error messages -47 system messages -47 – Avaya P580 User Manual

Page 227

Advertising
background image

Avaya P550R, P580, P880, and P882 Multiservice Switch User Guide, v5.3.1

5-47

Configuring Port Parameters

1. Enter Global Configuration mode.

The CLI displays the

<configure>#

prompt.

2. Enter the following command:

show hunt group internal-error-config

Error Messages

* Note: If IEDR detects errors on a port in the huntgroup, it tests

each port within that hunt group. When it finds the first
bad port, it removes it from the Hunt Group and disables
the port.

The IEDR feature may display the following error messages:

The following message indicates the IEDR feature is enabled
on the specified ports

internal-error-config enabled on port <x>/

<y>

The following message indicates that internal CRC errors are
occurring:

Description: CRC err: Rx'ed 5 bad pkts

since last poll - last from port3.2

The following message indicates that IEDR shut down a port
because its rate of internal errors exceeded the threshold:

Description: Shutdown Port 3.2 due to CRC

error exceeding threshold of 10

System Messages

The set port internal-error-shutdown all-ports enable
command produces system messages similar to the following:

Upon success:

Internal-error-config enabled on port 3/1

Internal-error-config enabled on port 3/2

Internal-error-config enabled on port 4/1

Internal-error-config enabled on port 4/2

Internal-error-config enabled on port 4/3

Internal-error-config enabled on port 4/4

Advertising
This manual is related to the following products: