7-10

Avaya P550R, P580, P880, and P882 Multiservice Switch User Guide, v5.3.1

Chapter

WARNING

To avoid bodily harm and equipment damage, you must power
off the switch before you remove switch controllers or elements.

5. Replace the failed controller.

6. Power on the switch power supplies and login.

7. Enable the redundant hardware (see "Enabling Redundant

Hardware" earlier in this chapter).

8. Re-select Switch Fabric from the System > Configuration

group on the Web Agent window. The Switch Fabric
Status
dialog box re-displays with the Switch Controller field
displaying:

# 1 Active

Replacing an Element

If an element fails, you are notified by:

An event log message

An error message that displays in the Switch Elements field

To replace a failed element:

1. Disable redundant hardware.

2. Copy the running config to the startup config.

3. Synchronize if you have redundant supervisor modules.

4. Power off the switch power supplies.

WARNING

To avoid bodily harm and equipment damage, you must power
off the switch before you remove switch controllers or elements.

5. Power on the switch power supplies and login.

6. Enable the redundant hardware (see "Enabling Redundant

Hardware" earlier in this chapter).

7. Replace the failed element.

8. Power on the switch’s power supplies and login.