To install redundant hardware:

1. Turn off all of the switch power supplies.

2. Replace the Primary switch controller with the new switch

controller. This ensures that the switch checks the status of
the new switch controller.

3. Insert the previously Primary switch controller into the

Redundant Controller Slot 1 (see Figure 6-17 for a P550/P580 or
Figure 6-18 for a P880/P882).

* Note: Controllers and elements are keyed to ensure that

a controller is not inserted into an element slot.

4. Install the redundant element into the redundant element slot 0

for the P550R/P580, (see Figure 6-17), or slot 6 for the P880/
P882, (see Figure 6-18).

5. Turn on the switch power supplies and log in.

6. Enable the Redundant Hardware as described in the next

section.

Enabling Redundant Hardware

Using the Web
Agent

To enable redundant hardware using the Web Agent:

1. Select Switch Fabric from the System > Configuration

group on the Web Agent window. The Switch Fabric
Status
dialog box opens. (Figure 6-19).