Warning, 4) operation, Input: type of electrical input (f – Yokogawa YVP110 User Manual

Page 22: Wiring procedure for grounding terminals

Advertising
background image

<1. Notes on Handling>

1-11

IM 21B04C01-01E

The grounding terminals are located on the inside

and outside of the terminal area.

Connect the cable to grounding terminal in

accordance with wiring procedure 1) or 2).

1) Internal grounding

terminal

2) External grounding

terminal

F0111.ai

Wiring Procedure for Grounding Terminals

(4) Operation

WARNING

• OPEN CIRCUIT BEFORE REMOVING

COVER. INSTALL IN ACCORDANCE WITH

THIS USER’S MANUAL

• Take care not to generate mechanical

sparking when access to the instrument and

peripheral devices in hazardous locations.

• Electrostatic charge may cause an explosion

hazard.

Avoid any actions that cause the generation

of electrostatic charge, such as rubbing with

a dry cloth on coating face of product.

• Carbon disulphide is excluded for enclosures

under gas atmosphere.

(5) Maintenance and Repair

WARNING

The instrument modification or parts replacement

by other than authorized Representative of

Yokogawa Electric Corporation is prohibited and

will void the certification.

(6) Name Plate

No. KEMA 08ATEX0114 X

II 1G Ex ia IIB/IIC T4

II 1D Ex iaD 20 IP65 T100°C

II 1D Ex tD A20 IP65 T100°C

ENCLOSURE:IP65

For II 1G Ex ia IIC or II 1D Ex iaD

Ui=24V Ii=250mA Pi=1.2W Ci=1.76nF Li=0µH

For II 1G Ex ia IIC/IIB or II 1D Ex iaD (FISCO field device)

Ui=17.5V Ii=380mA Pi=5.32W Ci=1.76nF Li=0µH

For II 1D Ex tD

Input signal:32V Output current:17mA

Tamb: −40 to 60°C

Tamb: −40 to 60°C

Tamb: −40 to 80°C

0344

II 1G,1D

N200

● Name plate for

intrinsically safe type

● Name plate for

flameproof type

WARNING

AFTER DE-ENERGIZING, DELAY 5 MINUTES

BEFORE OPENING.

WHEN THE AMBIENT TEMP.≥70°C,

USE THE HEAT-RESISTING CABLE & CABLE GLAND ≥90°C.

POTENTIAL ELECTROSTATIC CHARGING HAZARD.

SEE USER’S MANUAL BEFORE USE.
No. KEMA 10ATEX0023X

Ex d IIC T6,T5 Gb

SUPPLY 32V DC MAX

Tamb −40 TO 65°C(T6),80°C(T5)

ENCLOSURE : IP 65

0344

II 2G

N200

9 - 32 V DC Foundation Fieldbus

Foundation Fieldbus

F0110.ai

TOKYO 180-8750 JAPAN

TOKYO 180-8750 JAPAN

WARNING

DON'T OPEN WHEN ENERGIZED.

WHEN THE AMBIENT TEMP. ≥70°C

USE THE HEAT-RESISTING CABLE ≥90°C

F9176LL

YVP KS25

9-17.5(24)V DC (Ex ia, iaD) 9-32.0V DC (Ex tD)

Made in Japan

Made in Japan

F9176LK

YVP KF2

● Name plate for

/KN25 (Ex ic, Ex nA)

WARNING

WHEN THE AMBIENT TEMP.≥70°C,

USE THE HEAT-RESISTING CABLE & CABLE GLAND ≥90°C.

POTENTIAL ELECTROSTATIC CHARGING HAZARD.

- SEE USER’S MANUAL

DO NOT OPEN IN AN EXPLOSIVE ATMOSPHERE WHEN

ENERGIZED

CROSS OUT UNNECESSARY MARKING OTHER

THAN THE SELECTED TYPE OF PRPTECTION

II 3G

N200

TOKYO 180-8750 JAPAN

Made in Japan

F9176MQ

YVP KN25

Foundation Fieldbus

Ex ic IIC T4 Gc

Tamb −30 TO 75°C

ENCLOSURE : IP 65

Ui=32V, Ci=3.52nF, Li=0µH

Ex nA IIC T4 Gc

Tamb −30 TO 75°C

ENCLOSURE : IP 65

SUPPLY 32V DC MAX

*3

*3

*3

MODEL: Specified model code.

SUFFIX: Specified suffix code.

STYLE: Style code.

SUPPLY: Air supply pressure.

NO.: Serial number and year of production*

1

.

INPUT: Type of electrical input (F

OUNDATION

FIELDBUS).

TOKYO 180-8750 JAPAN:

The manufacturer name and the address*

2

.

*1:

The third figure from the last of the serial number shows

the year of production. For example, the production year

of the product engraved in “NO.” column on the name

plate as follows is 2001.

The year 2001

12A220566 108

*2:

“180-8750” is a zip code which represents the following

address.

2-9-32 Nakacho, Musashino-shi, Tokyo Japan

*3:

The production year is shown on the place of *3 (for

example “2013.02).”