36 activating hardware actions, 36 activating hardware actions -63 – Yokogawa DAQWORX User Manual

Page 110

Advertising
background image

4-63

IM WX102-01E

1

2

3

4

5

6

7

8

9

10

11

Index

DAR

WIN Hardware Configurator

4.36 Activating Hardware Actions

The following DA100, DC100, or DR hardware actions can be activated:

• System Restructuring.

• Initializing Hardware.
• Math: Start/Stop/Clear and Start/Clear.
• Report: Start/Stop.
• DC100 Writing Data Action: Start/Stop/Pause.
• Strain Balancing/Initialization/Object Input Channels. (Only for strain modules)

Math, Report, Writing and Strain actions can only be made if settings have first been

received from a DA100, DC100, or DR. After receiving the data, you may not have

changed the system, or module construction.

1

Select Comm. > Action > and choose the desired action.

An execution confirmation message appears, or a dialog box appears for select-
ing actions.

2.

If the confirmation message appears, click OK to execute the selected action.

If the action selection dialog box appears, select an action and then click OK. If
the execution confirmation message appears, click OK to execute the selected
action.

3.

If you select Balance (Strain Bal./Init.), set the type of initial balancing to execute.

Balance (Strain Balance): Executes initial balancing. Select an execution range

from the list box.

Initialize:

Restores the factory default settings.

Note

• If one of the below five settings have been altered, the following actions cannot be activated:

Math: Start/Stop/Clear and Start/Clear; Report: Start/Stop; DC100 Writing Data Action:
Start/Stop/Pause; Strain Balancing/Initialization/Object Input Channels.
• System configuration, or module construction.

• Initialization of edited data.

• Re-configuration.

• Initialization of DA100, DC100, DR.

• Writing method of measurement data.

• If the Logging monitor or record function is active following actions are impossible: Math:

Start/Stop/Clear and Start/Clear, Report: Start/Stop, DC100 Writing Data Action: Start/Stop/
Pause, the Strain Balancing/Initialization/Object Input Channels.

• If only altered settings are send event/action, Math, Report, or Memory Pause, LEVEL

actions, will not be canceled.

• When using ether communication, error detection may take a few minutes.