2 network settings, 2 network settings -2, Connection method – Yokogawa DAQWORX User Manual

Page 40: Network settings

Advertising
background image

3-2

IM WX102-01E

3.2

Network Settings

To use Ethernet for communication with DA100/DC100/DR, it is necessary to first make
IP address, Subnet Mask, and

Default Gateway settings for the DA100/DC100/DR.

Connection Method

Connect your PC to DA100/DC100/DR as described below. Connect only one DA100/
DC100/DR to one PC.

PC

Ethernet port

Ethernet module

Hub

10BASE-T cable

ETHERNET I/F

10BASE-T

DR

The Ethernet module mode must be the Set mode.

Network Settings

1

Switch on power of your PC and the DA100/DC100/DR, Startup DAQ 32 Plus and

select Software Configurator with the Launcher toolbar.

2

Click the Network tab to display the setting screen for IP address, Subnet Mask,

and Default Gateway (see below).

Network tab

Change after

colored blue

Dipswitch

position for

communication

mode

Dipswitch

position for

setting mode

Check button

3

Click the Check button to get the currently used settings. If this is the first time you
use the DA100/DC100/DR, initial values will get displayed.

4

If you click the digits in the IP address, Subnet Mask, or Default Gateway setting

boxes, the clicked part will be invertedly displayed, allowing you to change the

value.

Advertising